MCB Circuit Breaker C120N 1p 10Ka A9N18358 100A

Suitable for both AC and DC application – Din rail mountable

AC breaker 100A

DC breaker 100A

 

breaking capacity
3 kA Icu at 380…415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2

20 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2

15 kA Icu at 12 V DC conforming to EN/IEC 60947-2

15 kA Icu at 125 V DC conforming to EN/IEC 60947-2

10 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2

10 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2

20 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2

10000 A Icn at 230…400 V AC 50/60 Hz conforming to EN/IEC 60898-1

Complementary
network frequency
50/60 Hz
[Ue] rated operational voltage
380…415 V AC 50/60 Hz

125 V DC

<= 144 V DC

12 V DC

220…240 V AC 50/60 Hz

230…400 V AC 50/60 Hz

130 V AC 50/60 Hz

12 V AC 50/60 Hz

Reviews

There are no reviews yet.

Be the first to review “MCB Circuit Breaker C120N 1p 10Ka A9N18358 100A Nigeria made by schneider”

Your email address will not be published. Required fields are marked

Homaya Solar Hybrid System 850

130,000.00
Solar homaya hybrid home system 1500, powers both ac and dc loads from the smart synergy of solar and grid energy, homaya solar hybrid system range is ...
Add to cart

Conext MPPT 80 Solar PV Charge Controller 865-1032

1,561,699.00
Conext MPPT 80 Solar PV Charge Controller 865-1032 600V PV input, 48V battery Input, 80A current. Installing one MPPT 80 600 is faster than installing multiple smaller charge controllers and lowers overall costs further by utilizing fewer PV strings, smaller wiring and conduit, and by eliminating the need for PV combiner boxes and DC circuit breakers.
Add to cart

Voltage Regulator HTND-15KVA Himel Terminal connect Output 230V 1ph

411,999.00
HTND-15KVA (Cabinet) Terminal connect Output 220V With 02Fan
Servo Motor
Add to cart

MidNite Solar MNDC250

The MNDC Plus version of the popular MNDC adds another din rail allowing up to ten din rail mount breakers. Two din rail cover plates and two panel mount plates are included. The panel mount plates allow for mounting the ¾” 125VDC breakers that range from 60 amps to 100 amps. You can also fit the MNDC-GFP80 plus four more panel mount breakers in the enclosure. Another configuration would be one MNDC-GFP, one ¾” panel mount breaker and five din rail breakers as well as the large 125-250A inverter breaker. Mounting is provided for a 500 amp shunt and a MNTBB-R terminal bus bar. Battery negative stud is included as well as a ground busbar.
Read more